ISO 9001:2015 company.

For Support, please call 9326552525

If you have any suggestion, feedback or grievance kindly give us miss call on 08080881895 or email on This email address is being protected from spambots. You need JavaScript enabled to view it.

Minimum Lab setup : 1 Server + 10 Clients

Xtenda Setup is not allowed

 

Minimum Server Configuration

Dual Core Processor (2.4 Ghz) with 8 GB RAM

500GB Hard disk

Integrated Graphics

10/100 Mbps Ethernet Card

DVDROM Drive

Windows 7 x64(64-bit) Enterprise Edition with Service Pack 1

Antivirus

Quantity required per centre (minimum): 1 Desktop/Laptop

The above-mentioned server can support upto 10 clients. If number of clients are more, then server CPU and RAM should be increased proportionately

 

Minimum Client Configuration

Dual Core Processor 1.6 GHz Processor

4GB RAM

160GB Hard disk

10/100 BaseT PCI Ethernet

Sound Card

Keyboard and Mouse (Recommended Brand: Logitech, Microsoft etc.)

Headphone with Mic (Recommended Brand: Phillips, Intex, I-Ball etc.) for every client machine

Two Web Cameras (Recommended Brand: Logitech, Intex etc.) for every client machine

14inch SVGA Monitor or above (Recommended Brand: LG, Samsung etc.)

Windows 7 Enterprise/Ultimate (32-bit/64-bit) & MS Office 2013

Antivirus

Quantity required per centre (minimum): 10 Desktop/Laptops*

*Laptops are preferable because:

Consume less power

Require less space

Easy to maintain

Minimum 3-4 hours power backup available in case of power failure

Inbuilt Webcamera

Easy to move

WiFi connectivity

 

Licences

MKCL will provide the following licences to ALCs:

  1. Windows 7 x64 Enterprise Edition with Service Pack 1 – 1 Server Machine
  2. Windows 7 Enterprise (32-bit/64-bit) – 5 Client Machines
  3. MS Office 2013- 5 Client Machines

 

Peripherals

  • Printer - minimum 600 dpi resolution (Recommended Brand: HP, Canon, Epson etc.)
  • Scanner - minimum 600 dpi resolution (Recommended Brand: HP, Kodak etc.)
  • Bio Metric Device: (Any one from the following make & model)
    • enBioScan-C1 (HFDU08) from BioEnable or
    • MFS100 from Mantra Softech
  • Power Backup for all Computers
    • UPS (Recommended Brand: APC, Microtek, iBall etc.)
    • Inverter with Battery backup (Recommended Brand: APC, Microtek etc.)
    • DG Set (Optional)
  • CCTV (Optional)

 

LAN

10/100 Mbps Network Switch (Server and all Desktops should be connected to this Network Switch) (Recommended Brand: D-Link, Linksys etc.) OR Wifi Network

Electrical and LAN wiring should run perpendicular to each other. If they are parallel to each other, then a distance of 2 feet should be maintained between them to avoid interference

 

Internet

256Kbps Broadband Connection (Server and all Desktops should be able to connect to the Internet by using Internet Connection Sharing or Proxy Server)

Go to top